CAN connector pinouts should match this image. The yellow line is the edge of the board and the connector is mounted on the front in this caseimage.
...
M12
...
We use A-coded M12s with the following pinout:
TBD
Power sources use <TBD> contacts and devices that take power input use <TBD/opposite> contacts. All cables should then be male-to-female.
...
Connectors
Use | Connector Coding | Mating (From perspective of box-source and box-input) | Digikey Link | Locations |
---|---|---|---|---|
Ethernet Connection | D | Box Source: Female Box Input: Female | ||
Standard Data Transfer | D | Box Source: Male Box Input: Male | DAQ data transfer | |
Standard DC Power | A | Box Source: Female Wire Source: Male Box Sink: Male Wire Sink: Female | Standard power connector | |
High Current DC Power | T | Box Source: Female Box Input: Female | DAQ Power |
Power Pinout
...
Pin numbering starts from the left of the notch on a female connector, and goes clockwise
Pin 1: GND
Pin 2: 5V
Pin 3: 12V
Pin 4: 24V
Ethernet Pinout
We use D-coded M12s with the following (common in industry) pinout:
...
The ports on out boxes should have female contacts, and the wires linking the boxes together should be be male-to-male.