Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  1. Set up encoder motor set on skeleton board for software and firmware to test while mechanical fixes drive train issues

  2. If command send for close loop control does not work, power off and do not send additional commands as that will overheat motor driver in lock-in state. Motor driver and wires will overheat significantly and cause fumes and damage to rest of electronics

  3. Mechanical side will RCA on manufacturing and assembly side

  4. Grease the turning parts or using bearings to make connection smoother. Believe performance will be even better than now with working L2 set up

  5. Need to test all the motor without load and test the motor functionality

Outstanding tickets:

  •  <action name>, <Assignee>

...