CAN connector pinouts should match this image. The yellow line is the edge of the board and the connector is mounted on the front in this image.
...
M12 Power Connection
We use A-coded M12s with the following pinout:
TBD
Power sources use <TBD> contacts and devices that take power input use <TBD/opposite> contacts. All cables should then be male-to-female.Using information from Ultra Librarian on common uses for m12 keying
Type | Mating (From perspective of box-source and box-input) | Use | Digikey Link | Locations |
---|---|---|---|---|
D | Box Source: Female Box Input: Female | Ethernet Connection | Whatever is currently used in bay | |
D | Box Source: Male Box Input: Male | Standard Data Transfer | 708-2297-ND | DAQ data transfer |
A | Box Source: Female Box Input: Female | Low DC Power | Standard power connector | |
T | Box Source: Female Box Input: Female | High DC Power |
| RLCS, Laptop, Antenna |
M12 Pin outs for power:
...
Pin numbering starts from the left of the notch on a female connector, and goes clockwise
Pin 1: GND
Pin 2: 5V
Pin 3: 12V
Pin 4: 24V
M12 Ethernet Connection
We use D-coded M12s with the following (common in industry) pinout:
...