CAN connector pinouts should match this image. The yellow line is the edge of the board and the connector is mounted on the front in this image.

...

M12 Power Connection

We use A-coded M12s with the following pinout:

TBD

Power sources use <TBD> contacts and devices that take power input use <TBD/opposite> contacts. All cables should then be male-to-female.Using information from Ultra Librarian on common uses for m12 keying

Type

Mating (From perspective of box-source and box-input)

Use

Digikey Link

Locations

D

Box Source: Female

Box Input: Female

Ethernet Connection

Whatever is currently used in bay

D

Box Source: Male

Box Input: Male

Standard Data Transfer

A134516-ND

708-2297-ND
Note: Not a lot of cable options, might be better for Ethernet

DAQ data transfer

A

Box Source: Female

Box Input: Female

Low DC Power

A134451-ND or A133878-ND

A120960-ND

Standard power connector

T

Box Source: Female

Box Input: Female

High DC Power

1754-1060-ND


708-PXPTPU12FIM04TCL010PUR-ND (Cable kinda pricey)

RLCS, Laptop, Antenna

M12 Pin outs for power:

...

Pin numbering starts from the left of the notch on a female connector, and goes clockwise

Pin 1: GND

Pin 2: 5V

Pin 3: 12V

Pin 4: 24V



M12 Ethernet Connection

We use D-coded M12s with the following (common in industry) pinout:

...